Add estimated depth to the CAT4 locating workflow. This new CAT4+ includes StrikeAlert and provides depth estimation in Genny mode with a suitable signal. Choose it when you need depth without GPS usage logging. Genny4 and carry bag are optional.

What's in the Box

1 × new Radiodetection CAT4+ locator with depth estimation and StrikeAlert.

Genny4 and carry bag are not included.

Secure checkout

The Radiodetection CAT4+ is for teams who want the familiar CAT4 workflow with an additional depth estimate. It provides the same core locating modes as the standard CAT4, then adds a depth readout when used correctly in Genny mode with a suitable signal source.

Depth estimation when it is useful

Locate the service route, select Genny mode and follow the manufacturer procedure to obtain an estimated depth. For a line, use a suitable applied Genny signal; a compatible sonde can be used to locate within a non-metallic pipe. Depth estimates depend on signal quality and nearby services and must not be used to decide that mechanical digging is safe.

Radiodetection C.A.T4+ locator with depth estimation and StrikeAlert
New Radiodetection C.A.T4+ locator. Genny4 and carry bag are optional extras.

Everyday locating with StrikeAlert

Power, Radio and Genny modes help you investigate the available signals, with Avoidance mode for a combined initial sweep. This listing includes StrikeAlert for shallow detected services in supported modes. Dynamic Overload Protection helps manage electrical interference. Neither feature guarantees that every service will be detected.

Build the right locating kit

A new Genny4 signal generator or refurbished Genny4 lets you apply a traceable signal to a suitable service, rather than relying only on signals already present. It is optional with this standalone locator. Choose the connection method and accessories for the job, following the manufacturer instructions.

When clamp application is appropriate, a 100 mm Genny clamp connects to the transmitter, not directly to the CAT receiver. A used 100 mm clamp is another buying option. Check connector compatibility, service diameter and condition; clamp operation is not required for every direct connection.

For a non-metallic pipe or duct, a compatible 33 kHz S18A sonde or Standard 33 kHz sonde provides a locatable point. To push a suitable sonde through the route, compare 9 mm × 60 m Flexrod and 9 mm × 120 m Flexrod, checking the coupling and pipe clearance.

To trace an energised rod route instead, compare FlexiTrace 50 m and FlexiTrace 80 m. FlexiTrace needs a suitable transmitter connection; a plain Flexrod does not create that line-tracing signal.

For transport, choose the CAT4/CAT3 soft carry bag for the handheld instrument or compare the CAT-and-Genny soft bag for a combined kit. Arrange ongoing CAT and Genny servicing and calibration separately from the purchase warranty.

Which CAT4 model fits your work?

Choose CAT4+ for locating plus estimated depth. Choose the standard CAT4 if depth readout is unnecessary. Choose gCAT4+ if the team also needs usage logging, GPS/GNSS position records and compatible mobile data transfer; CAT4+ does not add those management functions.

An unused unit for your locating kit

New stock suits buyers who prefer unused equipment or need to meet a new-only purchasing policy. Select the optional Genny4 and carry bag to suit the kit you already own. If budget is the priority, the refurbished CAT4+ offers the same model-level depth function with a 12-month warranty and 12-month calibration.

Compare the refurbished CAT4+.

Watch the manufacturer application demonstration

How to locate streetlighting cables using the C.A.T4 Cable Avoidance Tool and Genny4 — Radiodetection. This shared family demonstration shows the locator used with a Genny4; it does not imply that a Genny4 is included in the base price or demonstrate every feature of this model.

Before you order

Is a Genny included?

No Genny is included in the base standalone-locator offer shown here. Select it in the existing options panel if required; check the chosen option’s contents.

Does it measure depth?

It estimates depth in Genny mode when the signal and operating conditions permit. Follow the line or sonde method in the operating instructions. A depth reading is not clearance to excavate.

Can it locate a plastic pipe on its own?

Not the unenergised plastic material itself. A suitable sonde or traceable rod system provides a signal that the locator can detect, subject to the application and operating conditions.

Does a quiet reading mean the area is clear?

No. Some services do not carry a detectable signal, and one response can mask another. Use the complete survey and safe excavation procedure required for your site, with the manufacturer operating instructions.

Check the technical details in More Information, and read the manufacturer operating instructions (V9) before use.

Prefer a complete CAT and Genny kit?

Compare the new CAT4+ and Genny4 kit. Check its base contents and optional extras before ordering; the refurbished kits offer a bag separately.